Question 1: Other functions of the moving head light are normal, prism or atomization can not be played or hit half, how to solve?
Answer: You must first disassemble the lamp to check whether the line and motor are normal. If the line and motor are normal, change the motherboard.
Question 2: After the power is turned on, the power indicator light is on, nothing else happens, the display does not light, the fan does not turn, and the light bulb does not light. How to do?
Answer: Open the base and look at the power line. If there is no problem with the line, change the power supply.
Question 3: Moving headlights are normal, but they are not controlled. What should I do?
Answer: We must first check if the address code of our lamp is broadcasted. The different control station broadcast address codes are different. If the address code is correct, check if the signal line is good. If the signal line is good, then The base of the lamp is turned on to see if the port receiving the signal is loose, or directly change the port for receiving a signal. If the signal receiving port is replaced, it will be replaced directly.
Question 4: There is a set of lamp beads that are not lit, what should I do?
Answer: Turn on the lamp, use a universal meter to measure the lamp beads, find the necrotic lamp beads, and solder the good lamp beads yourself.